42
ScanMaster User Guide
3.2 CODE 25 — INDUSTRIAL 25
By default, the scanner is set to read Industrial 25 barcodes.
Advanced settings are provided as shown below.
Start/Stop Selection
Select a desired start/stop pattern. For example, flight tickets actually use an Industrial 25
barcode but with Interleaved 25 start/stop pattern. In order to read this barcode, the start/stop
pattern selection of Industrial 25 should set to Interleaved 25.
Verify Checksum
Select the check box so that the scanner
will perform checksum verification when decoding
Industrial 25 barcodes. If the checksum is incorrect, the barcode will not be accepted.
Transmit Checksum
The checksum character will be included in the data being transmitted.
Cancel the check box if the checksum character is not desired.
Length Qualification
Because of the weak structure of the 2 of 5 barcodes, it is possible to make a "short scan" error.
To prevent the "short scan" error, configure the "Length Qualification" settings to ensure that the
correct barcode is read by qualifying the allowable code length. The barcode can be qualified by
"Fixed Length" or "Max/Min Length".
For "Fixed Length", up to 2 fixed lengths can be specified.
For "Max/Min Length", the maximum length and the minimum length must be specified. The
scanner will only accept those barcodes with lengths that fall between max/min lengths
specified.