CipherLab 1562 Betriebsanweisung Seite 31

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 160
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 30
19
Chapter 1
Changing Scanner Settings
Multi-Barcode Mode
The scanner will be scanning as long as the trigger is held down, capable of decoding one single
barcode, as well as a multiple unique barcodes one at a time. While decoding a bunch of unique
barcodes, if a barcode is decoded twice, its subsequent decoding will be ignored and the scanner
is expecting another unique barcode.
For the 2D scanners to decode multiple unique barcodes, the maximum output data length of all
the barcodes is 10 KB (1504/1564/1664) and 2042 bytes (1704) after configuration. When the
output length exceeds the maximum length allowed, Multi-Barcode Mode will not take effect.
The scanning won't stop until you release the trigger.
Note: (1) A barcode is considered unique when its Code Type or data is different from
others. (2) Multi-Barcode Mode has nothing to do with the Multi-Barcode Editor.
Presentation Mode (1504, 1564 and 1704 only)
The scanner will be expecting barcodes. Whenever a barcode is brought within range, the scanner
will be able to decode it. It is suggested to seat it in the Auto-Sense Stand for hands-free
operation.
1.1.1 SCANNING TIMEOUT
Specify the scanning time interval (1~254 sec.; 0= disable) when the scan mode is set to
any of the following scan mode –
Laser mode
Auto Off mode
Auto Power Off mode
Aiming mode
1.1.2 CONTINUOUS MODE DECODE DELAY
Set the time interval between each decoding when in Continuous Mode.
1.1.3 AIMING TIMEOUT
You can limit the aiming time interval (1~15 sec.) when in Aiming Mode. By default, the
scanner time-out is set to 1 second.