Quick Start
The example below shows how to set numeric parameters:
Steps
Action User Feedback if Successful
1 Power on the scanner... The scanner will respond with a long beep
(high tone) and its LED indicator will
become solid red and go off quickly.
2 Enter the Configuration Mode…
The scanner will respond with six beeps
(high-low tone repeats three times), and
its LED indicator will become flashing red.
Read a Setup label...
For example,
The scanner will respond with two beeps
(low-high tone) if reading a normal label.
3
The scanner will respond with one short
beep if reading a special label such as
“Max. Length”, indicating the setup
requires reading more labels.
Read the “Decimal Value” label(s).
Refer to Appendix IV “Decimal
System”
The scanner will respond with two beeps
(low-high tone) when the input values are
validated.
4 Exit the Configuration Mode…
OR
Same as for Enter the Configuration Mode.
5 The scanner will automatically restart itself… Same as for Power on the scanner.