Enter Setup
1660 Barcode Scanner
User Guide
3.2 CONNECTING VIA BLUETOOTH DONGLE
This is called "pairing with a Bluetooth device". The procedure for connecting the scanner
to a computer via a Bluetooth dongle is pretty much the same except for the software
you are using.
Note: When connecting more than two Bluetooth scanners to a computer via the
Bluetooth dongle, we suggest you to disable “Sniff Mode” for a more reliable
connection.
If your computer is running Microsoft Windows XP Service Pack 2 (SP2) or Windows Vista,
you can use the generic software support that Windows includes, or you can use the
driver that the device manufacturer provides.
Now, let’s try using the generic software support that Windows XP Service Pack 2
includes.
3.2.1 BLUETOOTH HID – ADD BLUETOOTH DEVICE WIZARD
By default, Bluetooth HID is activated on the 1660 scanner, and the keyboard type is set
to PCAT (US). When Bluetooth HID is re-activated, you will have to select a keyboard
type to complete this setting.
The procedure is the same as for Bluetooth SPP. Refer to steps 1~11 below.
3.2.2 BLUETOOTH SPP – ADD BLUETOOTH DEVICE WIZARD
1) Connect a Bluetooth dongle to your computer, running Windows XP SP2.
2) Double-click the Bluetooth icon fro the lower right of the taskbar.
Alternatively, you may go to Control Panel > Bluetooth Devices.
3) Click [Add] to search Bluetooth devices nearby.
4) Turn on the Bluetooth scanner with correct Bluetooth settings, such as select
Bluetooth SPP or Bluetooth HID, broadcasting enabled, authentication enabled, and
PIN code specified, etc. Select the check box of [My device is set up and ready to be
found] on your computer.
5) Click [Next].
6) Wait for a few seconds for the Wizard to search available Bluetooth devices nearby.
The scanner will appear with its “serial number” as the device name. You may
double-check the “Serial Number” label on the scanner to ensure connecting with the
correct scanner. Select the target scanner. If the target scanner does not appear on
the list, click [Search Again] to refresh the list. The scanner might enter Suspend
Mode now, and you can press the trigger to have it active again (=discoverable). It
will then stay active for one minute and wait for PC to establish a connection.
7) Click [Next].